GB CL TSH

PRODUCT DESCRIPTION

This reagent is an in-vitro diagnostic quantitative assay, using chemiluminescent immunoassay (CLIA) sandwich format, for measuring human TSH in serum or plasma. It requires 80 µL sample volume and delivers results in 20 minutes. With a detection limit of 0.015 µIU/mL, it detects very low TSH concentrations. Stored at 2-8°C, avoid light exposure and freezing. Ideal for diagnosing primary, pituitary, or hypothalamic causes of thyroid dysfunction and monitoring recovery or therapy.

PERFORMANCE

Limit of Quantitation (LoQ): 0.015 μIU/mL
PrecisionVariabilityCoefficient of variation, CV (%)
Repeatabilitywithin run<10%
Reproducibilitybetween-run/between-day<10%
between-sites/between-operators<10%
between-lots<10%

SPECIFICATION

PrincipleSandwich-type chemiluminescent immunoassay
Assay formatQuantification
Rreaction time20 minutes
Sample typeSerum/Plasma
Sample volume80 μL
Detection unitRelative light unit (RLU)
Storage2-8°C. Avoid exposure to direct sunlight. Do not freeze.
CertificationTFDA

ORDERING INFORMATION

Catalogue No.Product
4ATSH02GB CL TSH
4ATSH1BGB CL TSH-Control
4ATSH2BGB CL TSH-Calibrator

GB CL FT4

PRODUCT DESCRIPTION

This in vitro diagnostic quantitative reagent kit uses a competitive chemiluminescent immunoassay (CLIA) to measure free thyroxine (Free T4) in human serum or plasma. It requires 30 µL of specimen and features a 30-minute assay time. The analytical limit of quantification (LoQ) is 3.00 pmol/L. Precision is high: repeatability, reproducibility, and variation across locations/operators/batches all show CV <10%. The reagent is stored at 2-8°C, protected from light and not frozen. Certified under Taiwan FDA. Ideal for clinical thyroid function assessment and supportive diagnosis.

PERFORMANCE

Limit of Quantitation (LoQ): 3.00 pmol/L
PrecisionVariabilityCoefficient of variation, CV (%)
Repeatabilitywithin run<10%
Reproducibilitybetween-run/between-day<10%
between-sites/between-operators<10%
between-lots<10%

SPECIFICATION

PrincipleCompetition-type chemiluminescent immunoassay
Assay formatQuantification
Rreaction time30 minutes
Sample typeSerum/Plasma
Sample volume30 μL
Detection unitRelative light unit (RLU)
Storage2-8°C. Avoid exposure to direct sunlight. Do not freeze.
CertificationTFDA

ORDERING INFORMATION

Catalogue No.Product
4AFT402GB CL FT4
4AFT41BGB CL FT4-Control
4AFT42BGB CL FT4-Calibrator

GB CL FT3

PRODUCT DESCRIPTION

This in vitro diagnostic quantitative reagent kit uses a competitive chemiluminescent immunoassay format to measure free triiodothyronine (Free T3) in human serum or plasma. It requires a 30 µL sample, a 30-minute assay, and has a limit of quantification (LoQ) of 0.77 pmol/L. Stored at 2-8°C, protected from direct sunlight and not frozen. TFDA certified. Ideal for evaluating thyroid function and managing metabolic or endocrine disorders.

PERFORMANCE

Limit of Quantitation (LoQ): 0.77 pmol/L
PrecisionVariabilityCoefficient of variation, CV (%)
Repeatabilitywithin run<10%
Reproducibilitybetween-run/between-day<10%
between-sites/between-operators<10%
between-lots<10%

SPECIFICATION

PrincipleCompetition-type chemiluminescent immunoassay
Assay formatQuantification
Rreaction time30 minutes
Sample typeSerum/Plasma
Sample volume30 μL
Detection unitRelative light unit (RLU)
Storage2-8°C. Avoid exposure to direct sunlight. Do not freeze.
CertificationTFDA

ORDERING INFORMATION

Catalogue No.Product
4AFT302GB CL FT3
4AFT31BGB CL FT3-Control
4AFT32BGB CL FT3-Calibrator